NEW SCHNEIDER ELECTRIC WHITE PAPER RELEASE

INDUSTRY NEWS: posted 23 August 2018

PRESS RELEASE:  London, United Kingdom – Compressors are at the heart of all cooling systems. They are used in data centre applications to carry heat energy away from IT equipment and ensure it is cooled efficiently.

Their function is consistent in all cases: to compress a refrigerant from a low-pressure, low-temperature vapour, to a high-temperature, high pressure, and then push it through the refrigeration loop where the heat is rejected to the outdoors, or outside of a data centre. However, there are many different types of compressors, using a variety of techniques to accomplish the task.

A new White Paper from Schneider Electric, the leader in the digital transformation of energy management and automation, explains the technical differences between the many types of compressors popular in data centre applications and discusses the trade-offs that must be considered in each. Entitled “The Different Types of Cooling Compressors”, White Paper #254, outlines the inner functions of five common compressor types and explains how each performs the central task.

Compressors that come under the category of Positive Displacement technology make up four of the cooling mechanisms discussed. The most basic is the single-action reciprocating compressor or piston compressor which uses, as the name suggests, a piston and cylinder configuration to import low-pressure vapour and compress it to high-temperature high-pressure.

In hermetically sealed versions, such compressors are used in small applications although multi-cylinder variants in “open” configurations, which can be serviced in the field unlike the hermetically sealed variety, are also used in larger-scale industrial environments. Piston compressors are the lowest cost but are also the least efficent compressor discussed in the paper.

Rotary vane compressors are similar in operation to a piston compressor but a blade, or vane, splits the space between a fixed cylinder casing and a rolling piston, into two sections. As the piston rotates, these two volumes are increased and decreased to achieve gas suction, compression and removal of warm air. Rotary vane compressors have higher efficiency, smaller dimensions and lighter weight per unit capacity than piston compressors, in addition to being more reliable because of fewer components, reduced vibration and are less vulnerable to wear and tear.

Rotary scroll compressors, including those used in Schneider Electric’s Ecoflair™ Air Economizer and InRow™ close-coupled coolers, squeeze larger volumes of gaseous refrigerant to higher pressures and temperatures. The cool vapour refrigerant is drawn from outside the unit, compressed and finally removed from the centre via continuous displacement.

Rotary screw compressors compress large volumes of gaseous refrigerant to a high pressure and temperature. This is achieved by using male and female rotors that reduce the refrigerant gas volume as they rotate. Often found within cooling solutions such as Schneider Electric’s Aquaflair™ chiller, these models have larger capacity and higher efficiency due to a simpler structure and fewer components.They are suitable for larger data centre applications as it is impractical to design a capacity below 70kW due to the rotor processing technology.

The highest capacity, most efficient and expensive of the compressors are the centrifugal types, which are often used in the largest data centre enviroments. In these, instead of the refrigerant vapour being compressed in a cylinder, the vapour is compressed by adding kinetic energy via a rotating component.

Centrifugal compressors, sometimes called turbo or radial compressors, force cool vapour refrigerant through an impeller, which forces the fluid to spin ever faster. The high-speed gas is then passed through a diffuser where the refrigerant gas expands as its speed decreases. This process converts the kinetic energy of the high-speed low-pressure gas into a low-speed higher pressure gas.

White Paper No 254, “The Different Types of Cooling Compressors” is now available for free download at thttp://www.apc.com/wp?wp=254.

About the authors:

Paul Lin is a Senior Research Analyst at Schneider Electric's Data Center Science Center. He is responsible for data centre design and operation research and consults with clients on risk assessment and design practices to optimise the availabiity and efficiency of their data centre environments. He holds a master's degree in mechanical engineering from Jilin University.

Victor Avelar is a Director and Senior Research Analyst at Schneider Electric’s Data Center Science Center. He is responsible for data centre design and operations research and consults with clients on risk assessment and design practices to optimise the availability and efficiency of their data centre environments. He holds a bachelor’s degree in mechanical engineering from Rensselaer Polytechnic Institute and an MBA from Babson College.

About Schneider Electric:

Schneider Electric is leading the Digital Transformation of Energy Management and Automation in Homes, Buildings, Data Centers, Infrastructure and Industries.

With global presence in over 100 countries, Schneider is the undisputable leader in Power Management – Medium Voltage, Low Voltage and Secure Power, and in Automation Systems. We provide integrated efficiency solutions, combining energy, automation and software.

In our global Ecosystem, we collaborate with the largest Partner, Integrator and Developer Community on our Open Platform to deliver real-time control and operational efficiency.

We believe that great people and partners make Schneider a great company and that our commitment to Innovation, Diversity and Sustainability ensures that Life Is On everywhere, for everyone and at every moment.

For more information regarding Schneider Electric, please visit www.schneider-electric.com

Media Contact for Schneider Electric:

Lavina Dsouza Tel.: +44 (0) 7887 560218 / lavina.dsouza@Schneider-electric.com

Have your say...


Would you like to write your own Comment?



Your Comment

Your Name*
Please enter Your Name
Email Address*
Please enter an Email Address
Comment Subject*
Please enter a Comment Subject
Comments*
Please enter your Comments
 
RefreshPlay AudioHelp
 
I agree to the terms of use.
Please agree to the terms

There were errors. Please see the messages above.